KATA Ultrasonic Gas Meters are designed for measurement of consumed natural gas (see GOST 5542-2022 Standard), LPG vapor (see STB 2262-2012 Standard) or other non-aggressive gases for both production and domestic use.
Applicable scope includes housing and utilities sector, industrial and agricultural gas-consuming enterprises.
Components of the meter include a flow channel with ultrasonic sensors, an electronic module and a power supply. Classification of the meter: time-pulse ultrasonic flowmeter. The operational concept is measuring the difference in the travel time of short pulses along and against the flow.
Differences between the meter modifications:
meter size:
- G4
- G6
availability of additional devices:
- B (digital output)
- R (wireless data transmission channel)
- RK (wireless data transmission channel and valve)
fitting thread:
- G3/4
- G1
- G11/4
The meter modifications with a digital output or with a wireless data transmission channel can be fitted into an integrated automatic data collection and processing system.
Parameter |
Value |
|||||
KATA-G4 |
KATA-G6 |
|||||
Maximum flow rate Qmax |
6 m3/h |
10 m3/h |
||||
Transition flow rate Qt |
0.4 m3/h |
0.6 m3/h |
||||
Minimum flow rate Qmin |
0.04 m3/h |
0.06 m3/h |
||||
Sensitivity threshold, max |
0.024 m3/h |
0.04 m3/h |
||||
Pressure loss tolerance at maximum flow rate for different fitting threads, max |
310 Pa |
300 Pa |
200 Pa |
780 Pa |
700 Pa |
500 Pa |
G3/4 |
G1 |
G11/4 |
G3/4 |
G1 |
G11/4 |
|
Relative error limit under normal conditions: Qmin…Qt flow range >Qt…Qmax flow range |
±3% ±1.5% |
|||||
Counting device capacity (measured amount of gas in operating mode) |
99999 m3 |
|||||
Rated supply voltage from a DC source (lithium battery) |
3.6 V |
|||||
Consumption current, max |
0.060 mA |
|||||
Weight, max |
1.5 kg |
|||||
Overall dimensions, max |
130x100x215 mm |
|||||
Additional relative error limit for abnormal temperatures (other than +20±3℃) within the temperature range (i.e. extra delta to the relative error limit for every 10℃) |
±0.5 % |
|||||
Pipe fitting thread (as per GOST 6357-81 Standard) |
G3/4 G1 G11/4 |
|||||
Ambient temperature range |
-40℃…+55℃ |
|||||
IP rating (as per GOST 14254-2015 Standard) |
IP54 |
|||||
Relative air humidity @ +35℃, max |
95 % |
|||||
Measured gas temperature range |
- 40℃…+55℃ |
|||||
Peak pressure, max |
5 kPa |
|||||
Internal pressure limit (durability and tightness limit), max |
75 kPa |
|||||
Mean time between failures, min |
2500 hours |
In order to purchase the product you like, you must order it. There are several options to do that:
1. Order through our online store elicon.by
2. For invoicing, legal entities should contact:
- Optical Products Marketing & Sales Department
Tel: (+375 17) 215 11 21
Tel/fax: (+375 17) 356 95 56
Tel/fax: (+375 17) 356 85 57
E-mail: partners@belomo.by
- Automotive Components Marketing & Sales Department
Tel.: (+375 17) 325 44 70, 374 65 08
Tel/fax: (+375 17) 374 65 88
E-mail: uts.belomo@mail.ru
- Commercial Products and Consumer Goods (gas meters, compressors, consumer electronics, other consumer goods) Marketing & Sales Department
Tel.: (+375 17) 373 91 88
E-mail: barter@belomo.by