Control Units of IR-Radiators

Control unitsprovide for a function of point-to-point, piggy-back and planned laws of control of capacity of radiators, as well as automatic change-over from the mode of  maintenance of permissible minimum temperature at off-load equipment for a mode of optimum temperatures, at operating equipment and inversely.
 
The basic operating mode is the mode of automatic control of capacity, the manual mode is auxiliary and serves for switching on of radiators at failure of the system of automatic control.
 
TECHNICAL DATA:
 
Name of control unit
BUI.P-26
(2876-00)
BUI.P-13
(2876-01)
BUI.P-6.5
(2876-02)
BUI.S-52
(2877-00)
BUI.S-26
(2877-01)
BUI.S-13
(2877-02)
Law of power control
Point-to-point
Piggy-back
Peak load current, А
40
20
10
40
20
10
Peak load capacity, kW
26
13
6,5
52
26
13
Idle running power consumption, kW, max.
0,1
0,1
0,1
0,1
0,1
0,1
Electric shock protection class
1
1
1
1
1
1
Supply voltage, V
380
Frequency, Hz
50
Climatic version
UKHL4
Overall dimensions, mm (length, width, height), max.
450х300х565
Weight, kg, max.
20